| résistance à la compression: | ≥10 kPa | Matériel: | Laine minérale |
|---|---|---|---|
| Couleur: | Gris | Conductivité thermique: | 0,035 W/m·K |
| Coefficient d'absorption du son: | 0,85 | Méthode d'installation: | Fixation mécanique, collage |
| Dimensions: | Personnalisable (par exemple, planches de 600x1200 mm) | Application: | Isolation thermique et acoustique des bâtiments, équipements industriels |
| Épaisseur: | 20 à 100 mm | Absorption d'eau: | <1% |
| Résistance au feu: | Incombustible, classe A1 | Impact environnemental: | Recyclable et écologique |
| Résistance à la température: | -270°C à 700°C | Densité: | 40-200 kg/m³ |
| Mettre en évidence: | anti-condensation pipe insulation wrap,cold water pipe insulation wrap,chilled line thermal insulation |
||
Prevent costly moisture damage and maintain system efficiency with our Glass Wool Pipe Sections designed for condensation control. When insulating cold water pipes, chilled supply lines, or refrigeration pipes, our product effectively keeps the pipe surface temperature above the dew point. This prevents condensation from forming, which can lead to dripping, mold growth, and structural damage. It is an essential solution for protecting plumbing in walls, ceilings, and conditioned spaces.
![]()
![]()
Recommend Thickness List(mm)
Pipeline System Type | The Thickness of glasswood pipe shell applied in different pipeline(mm) | ||||||
|---|---|---|---|---|---|---|---|
Liquid Temperature Range℃ | Diameter of Branches Under 50mm | Under 25mm | 32-50 | 64-100 | 125-150 | Above 200mm | |
Air System Steaming and Water System High Temperature/ | 152-238 | 40 | 64 | 64 | 75 | 89 | 89 |
Medium Temperature/ | 122-151 | 40 | 50 | 64 | 64 | 75 | 75 |
low Temperature/ | 94-121 | 25 | 40 | 40 | 50 | 50 | 50 |
low Temperature System | 49-93 | 13 | 25 | 25 | 40 | 40 | 40 |
Steaming Condensator of Watering System | Any Temperature | 25 | 25 | 40 | 50 | 50 | 50 |
Equivalent Thickness of Surface Cooling Prevention
Environment | Relative Humidity | System Working Temperature | ||
|---|---|---|---|---|
2℃ | 7℃ | 13℃ | ||
38℃ | 50%-60% | 25 | 25 | 25 |
70% | 40 | 30 | 30 | |
80% | 75 | 60 | 50 | |
85% | 100 | 90 | 75 | |
32℃ | 50%-60% | 25 | 25 | 25 |
70% | 25 | 25 | 25 | |
80% | 50 | 50 | 40 | |
85% | 80 | 75 | 60 | |
27℃ | 50%-70% | 25 | 25 | 25 |
80% | 50 | 40 | 30 | |
85% | 75 | 65 | 50 | |
21℃ | 50%-70% | 25 | 25 | 25 |
80% | 50 | 40 | 30 | |
85% | 75 | 50 | 40 | |
If the humidity exceeds 90%, some cooling water will appeared on the surface. In this condition, adding the waterproofing coat or PVC plastic shell if necessary.
Density(kg/m3) | Thickness(mm) | Length (mm) | Diameter (mm) |
|---|---|---|---|
48-80 | 25-90 | 1000,1200 | 18-529 |
Condensation Prevention: Effectively controls "sweating" on cold pipes to protect building integrity.
Mold & Mildew Inhibitor: By keeping surfaces dry, it helps prevent the growth of harmful microorganisms.
Thermal Efficiency: Also provides excellent insulation to maintain desired fluid temperatures in cooling systems.
Easy Installation: Pre-formed sections allow for a snug, seamless fit that maximizes performance.
![]()
Aluminum foil facing
Foil-Scrim-Kraft Facing